OSHA SearchOSHA records by employer

Coffee County - Health Department: OSHA inspections and violations

Manchester, Tennessee · Administration of Public Health Programs · NAICS 923120

1inspections
3citation items
$0current penalties
Aug 2, 2019last inspection

OSHA inspectors have visited Coffee County - Health Department in Tennessee one time.

It opened on Aug 2, 2019 as a planned inspection, in Manchester.

In all, OSHA issued 3 citation items: 3 serious.

No penalty came with these citations.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Coffee County - Health Department averages $0 across 1 cited inspection.

Coffee County - Health Department: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

326employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Coffee County - Health Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344204433 OPENED AUG 2, 2019Closed

Planned · Complete · Safety · Local government · 10 employees at the site · Closed Oct 3, 2019

800 Park Street, Manchester, TN 37355 · Administration of Public Health Programs · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Aug 14, 2019Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Aug 14, 2019Final
Citation 1, item 3
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Aug 14, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.305(g)(1)(iv)

(iv) Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:

Other administration of public health programs employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.