OSHA SearchOSHA records by employer

Colby and Tobiason Custom Builders, Inc.: OSHA inspections and violations

Woodstock, Vermont · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
14citation items
$14,894current penalties
Oct 19, 2022last inspection

Colby and Tobiason Custom Builders, Inc. has 2 OSHA inspections on record in Vermont, the first in 2022.

OSHA's last visit started on Oct 19, 2022 after a complaint, in Woodstock.

Across those inspections OSHA issued 14 citation items: 13 serious and 1 other-than-serious.

OSHA proposed $28,320 in penalties. After settlements and reviews the total is $14,894, down 47%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Colby and Tobiason Custom Builders, Inc. averages $7,447 over 2 cited inspections in that time.

Colby and Tobiason Custom Builders, Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Colby and Tobiason Custom Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346292477 OPENED OCT 19, 2022Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Aug 14, 2023

63 Central St., Woodstock, VT 05091 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.62(d)(1)(i) · Lead in construction
Other-than-serious$349$349Nov 30, 2022Final

Inspection 345926737 OPENED APR 27, 2022Closed

Programmed other · Complete · Safety · 18 employees at the site · Closed Dec 7, 2022

45 Elm St, Woodstock, VT 05091 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,729$2,610Jul 22, 2022Final
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,351$0Jul 22, 2022Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$1,865$1,119Jul 22, 2022Final
Citation 1, item 3
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$4,351$2,610Jul 22, 2022Final
Citation 1, item 4
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$1,865$1,119Jul 22, 2022Final
Citation 1, item 5
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,865$1,119Jul 22, 2022Final
Citation 1, item 6a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,351$2,610Jul 22, 2022Final
Citation 1, item 6b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Jul 22, 2022Final
Citation 1, item 6c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jul 22, 2022Final
Citation 1, item 6d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jul 22, 2022Final
Citation 1, item 8
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$3,108$1,865Jul 22, 2022Final
Citation 1, item 9a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$2,486$1,493Jul 22, 2022Final
Citation 1, item 9b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Jul 22, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.150 · Fire protection

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.62 · Lead in construction

Other new single-family housing construction (except for-sale builders) employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.