OSHA SearchOSHA records by employer

Colonial Beach Town of: OSHA inspections and violations

Colonial Beach, Virginia · Water and Sewer Line and Related Structures Construction · NAICS 237110

3inspections
15citation items
$0current penalties
Apr 4, 2017last inspection

Colonial Beach Town of has 3 OSHA inspections on record in Virginia, the first in 2016.

OSHA's last visit started on Apr 4, 2017 to follow up on an earlier case, in Colonial Beach.

Across those inspections OSHA issued 15 citation items: 15 serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1926.651, excavations (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Colonial Beach Town of averages $0 over 2 cited inspections in that time.

Colonial Beach Town of: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Colonial Beach Town of and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342223351 OPENED APR 4, 2017Closed

Follow-up · Partial · Safety · Local government · 27 employees at the site · Closed Apr 20, 2017

Intersection Of 7th And Dwight Streets, Colonial Beach, VA 22443 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342078060 OPENED FEB 2, 2017Closed

Complaint · Partial · Safety · Local government · 3 employees at the site · Closed May 11, 2017

Rt 205 South Of Wilkersons Seafood, Colonial Beach, VA 22443 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(5)(ii)(c) · Permit-required confined spaces
Serious$0$0Apr 21, 2017Final
Citation 1, item 2
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Apr 21, 2017Final
Citation 1, item 3
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$0$0Apr 21, 2017Final
Citation 1, item 4
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Apr 21, 2017Final
Citation 1, item 5
29 CFR 1926.200(g)(1) · Accident prevention signs and tags
Serious$0$0Apr 21, 2017Final
Citation 1, item 6
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0Apr 21, 2017Final

Inspection 341875946 OPENED OCT 27, 2016Closed

Complaint · Complete · Safety · Local government · 27 employees at the site · Closed May 11, 2017

Intersection Of 7th And Dwight Streets, Colonial Beach, VA 22443 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Feb 21, 2017Final
Citation 1, item 2
29 CFR 1926.50(c) · Medical services and first aid
Serious$0$0Feb 21, 2017Final
Citation 1, item 3
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Feb 21, 2017Final
Citation 1, item 4
29 CFR 1926.200(g)(1) · Accident prevention signs and tags
Serious$0$0Feb 21, 2017Final
Citation 1, item 5
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Feb 21, 2017Final
Citation 1, item 6
29 CFR 1926.651(d) · Excavations
Serious$0$0Feb 21, 2017Final
Citation 1, item 7
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Feb 21, 2017Final
Citation 1, item 8
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Feb 21, 2017Final
Citation 1, item 9
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Feb 21, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(5)(ii)(c)

(C) Before an employee enters the space, the internal atmosphere shall be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. Any employee who enters the space, or that employee's authorized representative, shall be provided an opportunity to observe the pre-entry testing required by this paragraph.

29 CFR 1910.146(e)(1)

(e) Permit system. (1) Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit.

29 CFR 1910.146(g)(1)

(g) Training. (1) The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.21 · Construction safety training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.