Tualatin, Oregon · All Other Plastics Product Manufacturing · NAICS 326199
1inspections
7citation items
$200current penalties
Feb 12, 2019last inspection
OSHA has inspected Colorcoat Inc once in Oregon.
The inspection began on Feb 12, 2019 after a complaint, in Tualatin.
That inspection ended with 7 citation items: 3 serious and 4 other-than-serious.
Penalties were first proposed at $200 and still stand at $200.
Flammable liquids comes up most often in these citations: 3 items under 1910.106.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Colorcoat Inc averages $200 (1 cited inspection).
Colorcoat Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Oregon · latest 90 days of OSHA records
388employers cited
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Tualatin site logged 0 recordable injuries or illnesses among about 11 workers: 0.0 per 100 full-time workers, against a median of 2.5 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
ColorCoat Inc. Tualatin, OR
Tualatin · 2025
11
0
0
0.0
2.5
ColorCoat, Inc - Oregon
Tualatin · 2021
27
2
0
11.8
2.5
Included with any plan: 5 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.106(e)(9)(iii)
(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.