Inspection 345908008 OPENED APR 20, 2022Closed
4881 Sinclair Road, Columbus, OH 43229 · Car Washes · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Columbus Car Cleaning Company, Inc. 2 times in Ohio since 2019.
The latest one began on Apr 20, 2022 after a complaint, in Columbus.
Those inspections ended with 6 citation items: 6 serious.
Penalties were first proposed at $23,490 and now stand at $15,913, 32% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.
How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Columbus Car Cleaning Company, Inc. averages $15,913 (1 cited inspection).
1 inspection on this page followed a fatal incident.
Columbus Car Cleaning Company, Inc. also files yearly injury logs with OSHA, summarized below.
Ohio · latest 90 days of OSHA records
261employers cited
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch Columbus Car Cleaning Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company4881 Sinclair Road, Columbus, OH 43229 · Car Washes · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4881 Sinclair Road, Columbus, OH 43229 · Car Washes · OSHA's record · Phone and website on Google Maps
Incident on Jan 14, 2019 (fatal): Employee is pulled into machine when jacket is caught by cam
At 12:15 p.m. on January 14, 2019, an employee was preparing to add cloth and a bar to a Mitter machine at a car wash while the machine was in operation. The employee's jack was caught on the cam of the electric motor and he was pulled into the machine, crushing and killing him.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $5,304 | $3,600 | Feb 25, 2019 | Final |
| Citation 1, item 3a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $5,304 | $3,600 | Feb 25, 2019 | Final |
| Citation 1, item 3b 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Feb 25, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $5,304 | $3,600 | Feb 25, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $3,789 | $2,557 | Feb 25, 2019 | Final |
| Citation 1, item 6 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $3,789 | $2,556 | Feb 25, 2019 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2018, the Columbus site logged 0 recordable injuries or illnesses among about 35 workers: 0.0 per 100 full-time workers, against a median of 3.1 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Columbus Car Cleaning Company, Inc. Columbus · 2018 | 35 | 0 | 0 | 0.0 | 3.1 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(1)
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.219(d)(1)
(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.
29 CFR 1910.219(e)(1)(i)
(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.