OSHA SearchOSHA records by employer

Commonwealth Brothers LLC: OSHA inspections and violations

New Windsor, Maryland · Siding Contractors · NAICS 238170

1inspections
4citation items
$3,400current penalties
Apr 29, 2021last inspection

Commonwealth Brothers LLC has one OSHA inspection on record in Maryland.

OSHA opened it on Apr 29, 2021 after an accident, in New Windsor.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $3,400 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Commonwealth Brothers LLC averages $3,400 over 1 cited inspection in that time.

Commonwealth Brothers LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Commonwealth Brothers LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345281596 OPENED APR 29, 2021Closed

Accident · Partial · Safety · 5 employees at the site · Closed Jun 10, 2022

2808 Sams Creek Road, New Windsor, MD 21776 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,200$2,200Jul 1, 2021Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Jul 1, 2021Final
Citation 1, item 2a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$1,200$1,200Jul 1, 2021Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 1, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: