OSHA SearchOSHA records by employer

Condair Operations, LLC: OSHA inspections and violations

Richmond, Virginia · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

3inspections
6citation items
$30,368current penalties
Jul 13, 2026last inspection

Condair Operations, LLC has 3 OSHA inspections on record in Virginia, the first in 2026.

OSHA's last visit started on Jul 13, 2026 on a referral, in Richmond, and the case has not closed yet.

Across those inspections OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA proposed $40,490 in penalties. After settlements and reviews the total is $30,368, down 25%.

Most often, OSHA cited 1910.1048, formaldehyde (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Condair Operations, LLC averages $30,368 over 1 cited inspection in that time.

Condair Operations, LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Condair Operations, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Condair Operations, LLC at 2 sites in 2 states. Together they've had 4 inspections and $39,901 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 349049973 OPENED JUL 13, 2026Open

Referral · Partial · Safety · 150 employees at the site · Open

1410 Willis Road, Richmond, VA 23237 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 349046540 OPENED JUL 2, 2026Open

Complaint · Partial · Health · 106 employees at the site · Open

1410 Willis Road, Richmond, VA 23237 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348704560 OPENED JAN 22, 2026Closed

Complaint · Partial · Health · 81 employees at the site · Closed Oct 23, 2026

1410 Willis Road, Richmond, VA 23237 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(2) · Machine guarding
Serious$6,290$4,718Jul 14, 2026Final
Citation 1, item 2
29 CFR 1910.1048(d)(2) · Formaldehyde
Serious$11,400$8,550Jul 14, 2026Final
Citation 1, item 3a
29 CFR 1910.1048(n)(1) · Formaldehyde
Serious$11,400$8,550Jul 14, 2026Final
Citation 1, item 3b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jul 14, 2026Final
Citation 1, item 4 Serious$11,400$8,550Jul 14, 2026Final
Citation 2, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jul 14, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1048(d)(2)

(2) Initial monitoring. The employer shall identify all employees who may be exposed at or above the action level or at or above the STEL and accurately determine the exposure of each employee so identified.

29 CFR 1910.1048(l)(1)(i)

(l) Medical surveillance—(1) Employees covered. (i) The employer shall institute medical surveillance programs for all employees exposed to formaldehyde at concentrations at or exceeding the action level or exceeding the STEL.

29 CFR 1910.1048(n)(1)

(n) Employee information and training—(1) Participation. The employer shall assure that all employees who are assigned to workplaces where there is exposure to formaldehyde participate in a training program, except that where the employer can show, using objective data, that employees are not exposed to formaldehyde at or above 0.1 ppm, the employer is not required to provide training.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.