Conformatic Corp: OSHA inspections and violations

Guaynabo, Puerto Rico · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
3citation items
$2,350current penalties
Feb 7, 2017last inspection

Conformatic Corp has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Feb 7, 2017 on a referral, in Guaynabo.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $2,350 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Conformatic Corp averages $2,350 over 1 cited inspection in that time.

Conformatic Corp: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Conformatic Corp again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342089695 OPENED FEB 7, 2017Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jun 2, 2017

Centro Industrial Mario Julia Calle B Edificio 8 A, Guaynabo, PR 00969 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$1,000$1,000Mar 20, 2017Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$750$750Mar 20, 2017Final
Citation 1, item 3
29 CFR 1910.176(b) · Material storage and aisles
Serious$600$600Mar 20, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.36 · Exit route design

29 CFR 1910.36(d)(1)

(d) An exit door must be unlocked. (1) Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(a)(3)

(3) Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.

Other plumbing, heating, and air-conditioning contractors employers in Puerto Rico

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.