Inspection 346948003 OPENED AUG 30, 2023Closed
1031 Kearny St, Washington, DC 20017 · Other Activities Related to Real Estate · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Washington, District of Columbia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115
Since 2021, OSHA inspectors have visited Congressional Construction LLC in District of Columbia 2 times.
The most recent inspection opened on Aug 30, 2023, in Washington.
In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.
The proposed penalties came to $12,874; today they stand at $8,000, 38% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Congressional Construction LLC averages $8,000 across 1 cited inspection.
District of Columbia · latest 90 days of OSHA records
13employers cited
Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in District of Columbia
Checking a subcontractor, a client or your own company? Watch Congressional Construction LLC and get notified the morning OSHA posts a new citation for it.
Watch this company1031 Kearny St, Washington, DC 20017 · Other Activities Related to Real Estate · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3230 11th Street Nw, Washington, DC 20015 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $2,926 | $1,500 | Nov 19, 2021 | Final |
| Citation 1, item 2a 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $2,926 | $1,500 | Nov 19, 2021 | Final |
| Citation 1, item 2b 29 CFR 1926.405(d) · Job-site wiring |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 2c 29 CFR 1926.405(e)(1) · Job-site wiring |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 3a 29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements |
Serious | $4,096 | $3,500 | Nov 19, 2021 | Final |
| Citation 1, item 3b 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 3c 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 3d 29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 3e 29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $2,926 | $1,500 | Nov 19, 2021 | Final |
| Citation 2, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Nov 19, 2021 | Final |
| Citation 2, item 2 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Other-than-serious | $0 | $0 | Nov 19, 2021 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.102(a)(1)
(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.405(b)(2)
(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.