OSHA SearchOSHA records by employer

Congressional Construction LLC: OSHA inspections and violations

Washington, District of Columbia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
12citation items
$8,000current penalties
Aug 30, 2023last inspection

Since 2021, OSHA inspectors have visited Congressional Construction LLC in District of Columbia 2 times.

The most recent inspection opened on Aug 30, 2023, in Washington.

In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

The proposed penalties came to $12,874; today they stand at $8,000, 38% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Congressional Construction LLC averages $8,000 across 1 cited inspection.

Congressional Construction LLC: OSHA citation items per year, 2021 to 2023
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch Congressional Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346948003 OPENED AUG 30, 2023Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Feb 26, 2024

1031 Kearny St, Washington, DC 20017 · Other Activities Related to Real Estate · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345334593 OPENED MAY 27, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 27, 2022

3230 11th Street Nw, Washington, DC 20015 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,926$1,500Nov 19, 2021Final
Citation 1, item 2a
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,926$1,500Nov 19, 2021Final
Citation 1, item 2b
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Nov 19, 2021Final
Citation 1, item 2c
29 CFR 1926.405(e)(1) · Job-site wiring
Serious$0$0Nov 19, 2021Final
Citation 1, item 3a
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$4,096$3,500Nov 19, 2021Final
Citation 1, item 3b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Nov 19, 2021Final
Citation 1, item 3c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Nov 19, 2021Final
Citation 1, item 3d
29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements
Serious$0$0Nov 19, 2021Final
Citation 1, item 3e
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Nov 19, 2021Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,926$1,500Nov 19, 2021Final
Citation 2, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Nov 19, 2021Final
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Nov 19, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.