OSHA SearchOSHA records by employer

Conniff's Custom Building Co: OSHA inspections and violations

Hartford, Vermont · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
4citation items
$2,800current penalties
May 26, 2016last inspection

OSHA has inspected Conniff's Custom Building Co once in Vermont.

The inspection began on May 26, 2016, in Hartford.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $5,600 and now stand at $2,800, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Conniff's Custom Building Co averages $2,800 (1 cited inspection).

Conniff's Custom Building Co: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Conniff's Custom Building Co and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341506822 OPENED MAY 26, 2016Closed

Programmed other · Partial · Safety · 3 employees at the site · Closed Oct 17, 2016

Rt 14, Hartford, VT 05047 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$1,400Aug 22, 2016Final
Citation 1, item 1b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Aug 22, 2016Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Aug 22, 2016Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,800$1,400Aug 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.