OSHA SearchOSHA records by employer

Consolidated Container Company: OSHA inspections and violations

Atlanta, Georgia · Plastics Bottle Manufacturing · NAICS 326160

5inspections
4citation items
$31,966current penalties
May 15, 2019last inspection

Since 2004, OSHA inspectors have visited Consolidated Container Company in Georgia 5 times.

The most recent inspection opened on May 15, 2019 after a complaint, in Atlanta.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $36,031; today they stand at $31,966, 11% less.

The rule cited most here is 1910.147 (lockout/tagout), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Consolidated Container Company averages $10,655 across 3 cited inspections.

Consolidated Container Company also files yearly injury logs with OSHA, summarized below.

It reported 3 severe injuries to OSHA since 2015.

Consolidated Container Company: OSHA citation items per year, 2004 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Consolidated Container Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Consolidated Container Company at 21 sites in 8 states. Together they've had 50 inspections and $123,400 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 21 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 344349550 OPENED MAY 15, 2019Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Nov 13, 2019

400 Indeco Blvd Sw Ste A, Atlanta, GA 30336 · Plastics Bottle Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343029476 OPENED MAR 20, 2018Closed

Referral · Partial · Safety · 34 employees at the site · Closed Aug 20, 2018

6220 Duquesne Drive, Sw, Atlanta, GA 30336 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$12,934$12,934Jul 3, 2018Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$12,934$12,934Jul 3, 2018Final

Inspection 342901741 OPENED JAN 25, 2018Closed

Planned · Complete · Health · 54 employees at the site · Closed May 1, 2018

400 Indeco Drive, Suite A, Atlanta, GA 30336 · Plastics Bottle Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$10,163$6,098Apr 2, 2018Final

Inspection 340613074 OPENED MAY 6, 2015Closed

Referral · Partial · Safety · 60 employees at the site · Closed Jul 30, 2015

6220 Duquesne Drive, Sw, Atlanta, GA 30336 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 19, 2015Final

Inspection 306217266 OPENED JAN 13, 2004Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Jan 14, 2004

155 King Mill Road, Mcdonough, GA 30253 · Plastics Bottle Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Atlanta site logged 1 recordable injury or illness among about 64 workers: 1.4 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 3 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Consolidated Container Co. - Atlanta
Atlanta · 2019
64 111.42.6
Consolidated Container Co. - Fulton
Atlanta · 2019
52 101.72.6
Atlanta site
Atlanta · 2016
65 324.12.6
Fulton
Atlanta · 2016
53 101.92.6

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Mar 16, 2018, Atlanta: Amputation · amputations · fingertip(s)

An employee was clearing a jam from the blow molding machine and amputated the right index fingertip.

Jul 3, 2017, Atlanta: Hospitalization, amputation · amputations · fingertip(s)

An employee suffered a right index fingertip amputation while attempting to remove a bottle jam on a line. The line was unguarded and not locked/tagged out at the time.

Apr 29, 2015, Atlanta: Hospitalization · soreness, pain, hurt-nonspecified injury · hand(s), unspecified

An employee's right hand was caught while removing a mold jam causing his right hand to be severely pinched. The resulting injury required surgery.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other plastics bottle manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.