Inspection 343460580 OPENED SEP 13, 2018Closed
1110 Stevenson Drive, Springfield, IL 62703 · Plastics Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Sep 11, 2018: Employee's finger is amputated in baler machine
At 11:50 a.m. on September 11, 2018, an employee was aligning the baler head after changing from 10 inch to 8 inch head. The employee had his left hand in the machine attempting to tighten a bolt and his right hand on the controls when he inadvertently cycled the machine. The employee's finger was caught between a bolt and a limiting switch, resulting in an amputation of the tip of his left index finger. Hospitalization was not required.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(d) · Lockout/tagout |
Serious | $12,934 | $12,934 | Dec 11, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $9,239 | $0 | Dec 11, 2018 | Final |