OSHA SearchOSHA records by employer

Continental Microwave and Tool Co., Inc.: OSHA inspections and violations

Hampton, New Hampshire · Other Electronic Component Manufacturing · NAICS 334419

2inspections
4citation items
$2,500current penalties
Feb 10, 2016last inspection

OSHA has inspected Continental Microwave and Tool Co., Inc. 2 times in New Hampshire since 1990.

The latest one began on Feb 10, 2016 after a complaint, in Exeter.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $5,000 and now stand at $2,500, 50% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Continental Microwave and Tool Co., Inc. averages $2,500 (1 cited inspection).

Continental Microwave and Tool Co., Inc. also files yearly injury logs with OSHA, summarized below.

Continental Microwave and Tool Co., Inc.: OSHA citation items per year, 1990 to 2016
Citation items per year, by inspection date.

New Hampshire · latest 90 days of OSHA records

52employers cited

Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Hampshire

Checking a subcontractor, a client or your own company? Watch Continental Microwave and Tool Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341242295 OPENED FEB 10, 2016Closed

Complaint · Partial · Safety · 420 employees at the site · Closed May 12, 2016

11 Continental Drive, Exeter, NH 03833 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$5,000$2,500Mar 10, 2016Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$0$0Mar 10, 2016Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 10, 2016Final
Citation 1, item 1d
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$0$0Mar 10, 2016Final

Inspection 100850015 OPENED MAR 21, 1990Closed

Complaint · Partial · Safety · 83 employees at the site · Closed Apr 23, 1990

10 Merrill Dr., Hampton, NH 03842 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Exeter site logged 3 recordable injuries or illnesses among about 350 workers: 1.8 per 100 full-time workers, against a median of 0.0 for its industry. Those cases cost 1 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Continental Microwave & Tool Co
Exeter · 2017
350 311.80.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

Other other electronic component manufacturing employers in New Hampshire

Alert subscribers get notified of each newly cited employer in New Hampshire the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.