OSHA SearchOSHA records by employer

Continental Roofing Company, Inc.: OSHA inspections and violations

New Haven, Connecticut · Roofing Contractors · NAICS 238160

4inspections
27citation items
$12,125current penalties
Jul 13, 2015last inspection

OSHA has inspected Continental Roofing Company, Inc. 4 times in Connecticut since 2003.

The latest one began on Jul 13, 2015 as a planned inspection, in Collinsville.

Those inspections ended with 27 citation items: 27 serious.

Penalties were first proposed at $34,250 and now stand at $12,125, 65% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 12 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Continental Roofing Company, Inc. averages $2,000 (1 cited inspection).

Continental Roofing Company, Inc.: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

87employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Continental Roofing Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340771120 OPENED JUL 13, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 17, 2015

34 Bridge Street, Collinsville, CT 06022 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$1,000Jul 23, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,000Jul 23, 2015Final

Inspection 334248960 OPENED MAY 10, 2012Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 17, 2018

595 Whitney Ave, New Haven, CT 06511 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,200$400Aug 8, 2012Final
Citation 1, item 2
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 5
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 6a
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,000$680Aug 8, 2012Final
Citation 1, item 6b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Aug 8, 2012Final
Citation 1, item 7
29 CFR 1926.454(b) · Scaffold training
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 8
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,000Aug 8, 2012Final
Citation 1, item 9a
29 CFR 1926.454(a)(1) · Scaffold training
Serious$1,600$560Aug 8, 2012Final
Citation 1, item 9b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 8, 2012Final
Citation 1, item 10
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,600$560Aug 8, 2012Final

Inspection 123153280 OPENED MAR 16, 2005Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 18, 2005

Corner Of Skiff St. & Whitney Ave., North Haven, CT 06473 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$600$300Mar 29, 2005Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$450$225Mar 29, 2005Closed

Inspection 305930463 OPENED AUG 13, 2003Closed

Planned · Complete · Safety · 4 employees at the site · Closed Nov 26, 2003

415 Whitney Avenue, New Haven, CT 06511 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 1b
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$0$0Oct 29, 2003Closed
Citation 1, item 1c
29 CFR 1926.404(f)(7)(ivb) · Ground-fault protection on job sites
Serious$0$0Oct 29, 2003Closed
Citation 1, item 1d
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Oct 29, 2003Closed
Citation 1, item 2
29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 3
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 4
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 6
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 7
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$1,500$450Oct 29, 2003Closed
Citation 1, item 8
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$1,500$450Oct 29, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.