Petrolia, Pennsylvania · Other Heavy and Civil Engineering Construction · NAICS 237990

1inspections
6citation items
$59,581current penalties
Nov 22, 2025last inspection

OSHA has inspected Conway-Phillips Holding, LLC once in Pennsylvania.

The inspection began on Nov 22, 2025 after a fatality or catastrophe, in Petrolia; the case is still open.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $59,581 and still stand at $59,581.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Conway-Phillips Holding, LLC averages $59,581 (1 cited inspection).

Conway-Phillips Holding, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Conway-Phillips Holding, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348612102 OPENED NOV 22, 2025Open

Fatality or catastrophe · Partial · Safety · 65 employees at the site · Open

100 Sonneborn Lane, Petrolia, PA 16050 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$16,550$16,550May 19, 2026Contested
Citation 1, item 1b
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0May 19, 2026Contested
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$16,550$16,550May 19, 2026Contested
Citation 1, item 3
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$16,550$16,550May 19, 2026Contested
Citation 1, item 4a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$9,931$9,931May 19, 2026Contested
Citation 1, item 4b
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$0$0May 19, 2026Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.502 · Fall protection systems

Other other heavy and civil engineering construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.