Inspection 342751674 OPENED NOV 4, 2017Closed
683 Jones Bayou Road, Shaw, MS 38773 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Incident on Nov 3, 2017 (fatal): Employee is electrocuted when pipe contacts overhead power l
At 3:30 p.m. on November 3, 2017, an employee was installing 40 foot section of galvanized pipe into a well pump. The 40 foot section of galvanized pipe fell onto an overhead power line while the employee was holding the pipe. The employee was electrocuted.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1408(a)(2) · Power line safety (up to 350 kV)—equipment operations |
Serious | $12,934 | $12,934 | Apr 23, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.1425(c)(2) · Keeping clear of the load |
Serious | $3,880 | $3,880 | Apr 23, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.1430(a) · Training |
Serious | $3,880 | $3,880 | Apr 23, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.1433(d)(6) · Design, construction and testing |
Serious | $1,663 | $1,663 | Apr 23, 2018 | Final |
| Citation 2, item 1 29 CFR 1926.251(a)(2)(i) · Rigging equipment for material handling |
Other-than-serious | $0 | $0 | Apr 23, 2018 | Final |
| Citation 2, item 2 29 CFR 1926.1412(e)(3)(i) · Inspections |
Other-than-serious | $0 | $0 | Apr 23, 2018 | Final |
| Citation 2, item 3 29 CFR 1926.1412(f)(1) · Inspections |
Other-than-serious | $0 | $0 | Apr 23, 2018 | Final |