OSHA SearchOSHA records by employer

Cool-Vue Aluminum, Inc.: OSHA inspections and violations

New Orleans, Louisiana · Metal Window and Door Manufacturing · NAICS 332321

5inspections
13citation items
$3,683current penalties
Jul 12, 2018last inspection

OSHA has inspected Cool-Vue Aluminum, Inc. 5 times in Louisiana since 1974.

The latest one began on Jul 12, 2018 as a planned inspection, in Kenner.

Those inspections ended with 13 citation items: 5 serious and 8 other-than-serious.

Penalties were first proposed at $7,896 and now stand at $3,683, 53% lower after settlements or reviews.

Walking-working surfaces comes up most often in these citations: 3 items under 1910.22.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Cool-Vue Aluminum, Inc. averages $3,548 (1 cited inspection).

Cool-Vue Aluminum, Inc.: OSHA citation items per year, 1974 to 2018
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Cool-Vue Aluminum, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343300026 OPENED JUL 12, 2018Closed

Planned · Complete · Safety · 10 employees at the site · Closed Mar 12, 2020

2624 Delaware Ave., Kenner, LA 70062 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,772$1,386Sep 25, 2018Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,326$1,330Sep 25, 2018Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,663$832Sep 25, 2018Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Sep 25, 2018Final
Citation 1, item 3c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Sep 25, 2018Final

Inspection 342026838 OPENED JAN 11, 2017Closed

Planned · No inspection · Safety · 9 employees at the site · Closed Jan 13, 2017

2624 Delaware Avenue, Kenner, LA 70062 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310253695 OPENED SEP 20, 2007Closed

Planned · No inspection · Safety · Closed Sep 21, 2007

2008 Saint Ferdinand Street, New Orleans, LA 70117 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 16356925 OPENED DEC 19, 1974Closed

Follow-up · Partial · Safety · 13 employees at the site · Closed Mar 10, 1984

2008 St Ferdinand Street, New Orleans, LA 70117 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 16356859 OPENED NOV 25, 1974Closed

Planned · Partial · Safety · 13 employees at the site · Closed Jan 7, 1975

2008 St Ferdiand Street, New Orleans, LA 70117 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$25$25Nov 26, 1974Closed
Citation 1, item 2
29 CFR 1910.22(b)(2) · General requirements
Other-than-serious$30$30Nov 26, 1974Closed
Citation 1, item 3
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 26, 1974Closed
Citation 1, item 4
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$25$25Nov 26, 1974Closed
Citation 1, item 5
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$55$55Nov 26, 1974Closed
Citation 1, item 6
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Nov 26, 1974Closed
Citation 1, item 7
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 26, 1974Closed
Citation 1, item 8 Other-than-serious$0$0Nov 26, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.309

Other metal window and door manufacturing employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.