OSHA SearchOSHA records by employer

Coomer Electric Inc.: OSHA inspections and violations

Wise, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
5citation items
$640current penalties
Aug 20, 2015last inspection

OSHA has inspected Coomer Electric Inc. 3 times in Virginia since 2000.

The latest one began on Aug 20, 2015 after a complaint, in Norton.

Those inspections ended with 5 citation items: 2 serious and 3 other-than-serious.

Penalties were first proposed at $735 and now stand at $640, 13% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Coomer Electric Inc. averages $420 (1 cited inspection).

Coomer Electric Inc.: OSHA citation items per year, 2000 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Coomer Electric Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340861764 OPENED AUG 20, 2015Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Feb 23, 2016

Norton Community Hospital 100 15th Street Nw, Norton, VA 24273 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$420$420Oct 1, 2015Final
Citation 2, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Oct 1, 2015Final

Inspection 316787100 OPENED NOV 8, 2012Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Aug 28, 2013

Appalachia Elementary School, Appalachia, VA 24216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$315$220Jan 16, 2013Closed
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Jan 16, 2013Closed

Inspection 303249999 OPENED MAR 15, 2000Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed May 15, 2000

211 Railroad Avenue, Wise, VA 24293 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Other-than-serious$0$0Apr 25, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.