OSHA SearchOSHA records by employer

Cooper Canyon Boutique Trailers and Tanks, LLC: OSHA inspections and violations

El Paso, Texas · Cement Manufacturing · NAICS 327310

1inspections
7citation items
$9,000current penalties
Nov 8, 2016last inspection

OSHA has inspected Cooper Canyon Boutique Trailers and Tanks, LLC once in Texas.

The inspection began on Nov 8, 2016 after a complaint, in El Paso.

That inspection ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $17,501 and now stand at $9,000, 49% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 4 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Cooper Canyon Boutique Trailers and Tanks, LLC averages $9,000 (1 cited inspection).

Cooper Canyon Boutique Trailers and Tanks, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Cooper Canyon Boutique Trailers and Tanks, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341900439 OPENED NOV 8, 2016Closed

Complaint · Partial · Safety · 17 employees at the site · Closed Dec 17, 2020

4560 Ripley Dr., El Paso, TX 79922 · Cement Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$4,988$2,500Dec 23, 2016Final
Citation 1, item 2 Serious$2,850$1,450Dec 23, 2016Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,563$1,750Dec 23, 2016Final
Citation 1, item 4a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,850$1,450Dec 23, 2016Final
Citation 1, item 4b
29 CFR 1910.305(b)(3)(i) · Electrical wiring methods
Serious$0$0Dec 23, 2016Final
Citation 1, item 5
29 CFR 1910.305(j)(1)(iii) · Electrical wiring methods
Serious$2,850$1,450Dec 23, 2016Final
Citation 2, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$400$400Dec 23, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.95 · Noise

Other cement manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.