OSHA SearchOSHA records by employer

Cornerstone Roofing, Ltd: OSHA inspections and violations

Mckinney, Texas · Roofing Contractors · NAICS 238160

4inspections
2citation items
$5,132current penalties
Jun 23, 2016last inspection

Cornerstone Roofing, Ltd has 4 OSHA inspections on record in Texas, the first in 2004.

OSHA's last visit started on Jun 23, 2016 as a planned inspection, in Irving.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $8,553 in penalties. After settlements and reviews the total is $5,132, down 40%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Cornerstone Roofing, Ltd averages $5,132 over 1 cited inspection in that time.

Cornerstone Roofing, Ltd: OSHA citation items per year, 2004 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Cornerstone Roofing, Ltd again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341575785 OPENED JUN 23, 2016Closed

Planned · Partial · Safety · 5 employees at the site · Closed Aug 24, 2016

7207 Marquis Ln., Irving, TX 75063 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,989$2,993Aug 12, 2016Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,564$2,138Aug 12, 2016Final

Inspection 312125784 OPENED DEC 16, 2009Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Mar 10, 2010

700 Shiloh Rd, Plano, TX 75074 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309536407 OPENED JAN 26, 2006Closed

Referral · Partial · Safety · 4 employees at the site · Closed May 5, 2006

Corner Of Deercreek & Blackwolf Run, Frisco, TX 75035 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305470072 OPENED FEB 18, 2004Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Apr 16, 2004

2912 Gabriel Dr., Mckinney, TX 75071 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.