Inspection 341680932 OPENED JUL 7, 2016Closed
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1987, OSHA inspectors have visited Corning Painted Post CSD Bus Garage in New York 13 times.
The most recent inspection opened on Jul 7, 2016 to follow up on an earlier case, in Corning.
In all, OSHA issued 37 citation items: 20 serious and 17 other-than-serious.
No penalty came with these citations.
The rule cited most here is 1910.303 (electrical equipment, general requirements), 9 times.
Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $2,416 penalty. Corning Painted Post CSD Bus Garage averages $0 across 1 cited inspection.
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Corning Painted Post CSD Bus Garage and get notified the morning OSHA posts a new citation for it.
Watch this company2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $0 | $0 | Jun 15, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Jun 15, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Jun 15, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jun 15, 2016 | Final |
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 2 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 3 29 CFR 1910.106(g)(3)(iii) · Flammable liquids |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 4 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 5 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 6 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
| Citation 1, item 7 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Serious | $0 | $0 | Feb 15, 2012 | Closed |
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 2 29 CFR 1910.37(a)(2) · Exit routes |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 3 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 4 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 5 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 6 29 CFR 1910.305(e)(1) · Electrical wiring methods |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 1, item 7 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.106(g)(8) · Flammable liquids |
Other-than-serious | $0 | $0 | Nov 23, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 23, 2007 | Closed |
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jun 9, 1998 | Closed |
| Citation 1, item 2 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 9, 1998 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 9, 1998 | Closed |
| Citation 1, item 4 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 9, 1998 | Closed |
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.242(b) · Hand and power tools |
Serious | $0 | $0 | Oct 5, 1992 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 5, 1992 | Closed |
| Citation 1, item 3 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Oct 5, 1992 | Closed |
| Citation 2, item 1 29 CFR 1910.169(b)(2) · Air receivers |
Other-than-serious | $0 | $0 | Oct 5, 1992 | Closed |
| Citation 2, item 2 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 5, 1992 | Closed |
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.177(d)(5) · Servicing multi-piece and single piece rim wheels |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
| Citation 1, item 2 29 CFR 1910.242(a) · Hand and power tools |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
| Citation 1, item 3 29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
| Citation 1, item 4 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
| Citation 1, item 5 29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
| Citation 1, item 6 29 CFR 1910.305(g)(1)(iia) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Oct 3, 1989 | Closed |
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2666 Goff Rd, Corning, NY 14830 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 18, 1987 | Closed |
| Citation 1, item 2 29 CFR 1910.303(g)(2)(ib) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 18, 1987 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(g)(3)(iii)
(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.
29 CFR 1910.106(g)(8)
(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.
29 CFR 1910.1200(e)(1)(i)
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.