OSHA SearchOSHA records by employer

Corsair Electrical Connectors, Inc.: OSHA inspections and violations

Irvine, California · Current-Carrying Wiring Device Manufacturing · NAICS 335931

2inspections
9citation items
$24,900current penalties
Apr 17, 2017last inspection

Corsair Electrical Connectors, Inc. has 2 OSHA inspections on record in California, the first in 2008.

OSHA's last visit started on Apr 17, 2017 after an accident, in Irvine.

Across those inspections OSHA issued 9 citation items: 1 serious and 8 other-than-serious.

OSHA proposed $38,080 in penalties. After settlements and reviews the total is $24,900, down 35%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Corsair Electrical Connectors, Inc. averages $24,500 over 1 cited inspection in that time.

Corsair Electrical Connectors, Inc.: OSHA citation items per year, 2008 to 2017
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,138employers cited

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Corsair Electrical Connectors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342264199 OPENED APR 17, 2017Closed

Accident · Partial · Safety · 100 employees at the site · Closed Oct 5, 2020

17100 Murphy Ave., Irvine, CA 92614 · Electronic Connector Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Apr 4, 2017: Employee amputates thumb in unguarded part of a molding mach

At approximately 11:45 a.m. on April 4, 2017, Employee #1 was in the shop area molding department of a manufacturer of electrical connectors for the military and aerospace industries. He was working on the BOY 80M molding machine changing out a part in the pneumatic rubber feeder. Employee #1 removed the rubber feeding cylinder from the top of the machine and disconnected the airlines that went to it so he could bring it down and replace a part inside the cylinder. He then needed to move the plunger inside the cylinder to remove old rubber material, so he plugged in the airline and at that time it activated the cylinder and his thumb was inadvertently inside an unguarded place on the cylinder. The plunger came down and amputated his left thumb. The employer did not have hazardous energy control procedures (HECP's) when maintaining and servicing or repairing the machine and the cylinder had an unguarded section with moving parts. If the cylinder had been properly guarded and having HECP's in place this could have prevented the injury. Employee #1 was transported to a medical center, where he received treatment and was then hospitalized. hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 342(A)
Other-than-serious$5,000$5,000Jul 11, 2017Final
Citation 1, item 2
29 CFR 3203(A)
Other-than-serious$560$450Jul 11, 2017Final
Citation 1, item 3
29 CFR 3314(L)(1)
Other-than-serious$700$450Jul 11, 2017Final
Citation 2, item 1
29 CFR 4002(A)
Other-than-serious$8,435$600Jul 11, 2017Final
Citation 3, item 1
29 CFR 3314(G)(2)(A)
Serious$22,500$18,000Jul 11, 2017Final

Inspection 309302081 OPENED JUL 14, 2008Closed

Complaint · Partial · Health · 67 employees at the site · Closed Jun 16, 2009

16752 Millikan Ave, Irvine, CA 92606 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$160$160Dec 31, 2008Final
Citation 1, item 2
29 CFR 3203 A
Other-than-serious$325$0Dec 31, 2008Final
Citation 1, item 3
29 CFR 3314 G02
Other-than-serious$240$240Dec 31, 2008Final
Citation 1, item 4
29 CFR 5144 C01
Other-than-serious$160$0Dec 31, 2008Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 2500.8

Other current-carrying wiring device manufacturing employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.