OSHA SearchOSHA records by employer

Courtney Cleaners: OSHA inspections and violations

Sanford, Maine · Drycleaning and Laundry Services (except Coin-Operated) · NAICS 812320

1inspections
2citation items
$1,400current penalties
Apr 2, 2015last inspection

OSHA has inspected Courtney Cleaners once in Maine.

The inspection began on Apr 2, 2015 after a complaint, in Sanford.

That inspection ended with 2 citation items: 1 serious and 1 other-than-serious.

Penalties were first proposed at $2,800 and now stand at $1,400, 50% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Courtney Cleaners averages $1,400 (1 cited inspection).

Courtney Cleaners: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Courtney Cleaners and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340513589 OPENED APR 2, 2015Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jan 20, 2016

1298 Main Street, Sanford, ME 04073 · Drycleaning and Laundry Services (except Coin-Operated) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,800$1,400Apr 15, 2015Final
Citation 2, item 1
29 CFR 1910.305(a)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(i)

(i) Temporary electrical power and lighting installations of 600 volts, nominal, or less may be used only as follows:

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other drycleaning and laundry services (except coin-operated) employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.