OSHA SearchOSHA records by employer

CPX2024XTN976X0029 - Lee's Pipelines, Inc.: OSHA inspections and violations

Gilbert, Arizona · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$23,439current penalties
Jan 8, 2024last inspection

OSHA inspectors have visited CPX2024XTN976X0029 - Lee's Pipelines, Inc. in Arizona one time.

It opened on Jan 8, 2024 after a complaint, in Gilbert.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $23,439 in total, stand where OSHA first set them.

The rule cited most here is 1926.652 (trench protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. CPX2024XTN976X0029 - Lee's Pipelines, Inc. averages $23,439 across 1 cited inspection.

CPX2024XTN976X0029 - Lee's Pipelines, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

84employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch CPX2024XTN976X0029 - Lee's Pipelines, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347232837 OPENED JAN 8, 2024Closed

Complaint · Partial · Health · 14 employees at the site · Closed Nov 1, 2024

435 South Hamilton Court, Gilbert, AZ 85233 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$7,813$7,813Jun 28, 2024Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$7,813$7,813Jun 28, 2024Final
Citation 1, item 3a
29 CFR 1926.652(c)(2)(i) · Trench protection
Serious$7,813$7,813Jun 28, 2024Final
Citation 1, item 3b
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$0$0Jun 28, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(c)(2)(i)

(2) Option (2)—Designs Using Manufacturer's Tabulated Data. (i) Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.

Other water and sewer line and related structures construction employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.