OSHA SearchOSHA records by employer

CR Masonry: OSHA inspections and violations

Oklahoma City, Oklahoma · Masonry Contractors · NAICS 238140

1inspections
5citation items
$4,546current penalties
Nov 15, 2019last inspection

CR Masonry has one OSHA inspection on record in Oklahoma.

OSHA opened it on Nov 15, 2019 as a planned inspection, in Oklahoma City.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $4,546 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. CR Masonry averages $4,546 over 1 cited inspection in that time.

CR Masonry: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites CR Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344452495 OPENED NOV 15, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 7, 2023

Nw 36th & Walker, Oklahoma City, OK 73118 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,273$2,273Dec 13, 2019Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Dec 13, 2019Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,273$2,273Dec 13, 2019Final
Citation 1, item 2b
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$0$0Dec 13, 2019Final
Citation 1, item 2c
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Dec 13, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other masonry contractors employers in Oklahoma

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.