OSHA SearchOSHA records by employer

Craddock Masonry Inc.: OSHA inspections and violations

Richmond, Virginia · Masonry Contractors · NAICS 238140

3inspections
12citation items
$6,834current penalties
Nov 18, 2024last inspection

Since 1994, OSHA inspectors have visited Craddock Masonry Inc. in Virginia 3 times.

The most recent inspection opened on Nov 18, 2024 on a referral, in Ashland.

In all, OSHA issued 12 citation items: 6 serious and 6 other-than-serious.

The proposed penalties came to $13,978; today they stand at $6,834, 51% less.

The rule cited most here is 1926.59 (hazard communication), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Craddock Masonry Inc. averages $6,346 across 1 cited inspection.

Craddock Masonry Inc.: OSHA citation items per year, 1994 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Craddock Masonry Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347883704 OPENED NOV 18, 2024Closed

Referral · Partial · Safety · 18 employees at the site · Closed May 28, 2025

8099 Prospect Lane, Ashland, VA 23005 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,762$3,096Mar 11, 2025Final
Citation 1, item 2a
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$3,175$0Mar 11, 2025Final
Citation 1, item 2b
29 CFR 1926.454(b) · Scaffold training
Other-than-serious$0$0Mar 11, 2025Final
Citation 1, item 2c
29 CFR 1926.454(c) · Scaffold training
Other-than-serious$0$0Mar 11, 2025Final
Citation 2, item 1
29 CFR 40.1-51.1.D.II
Other-than-serious$5,000$3,250Mar 11, 2025Final
Citation 2, item 2
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$65$0Mar 11, 2025Final
Citation 2, item 3
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Mar 11, 2025Final

Inspection 342993730 OPENED MAR 3, 2018Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Sep 4, 2018

4024 Glenside Ave, Henrico, VA 23228 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125459263 OPENED AUG 12, 1994Closed

Referral · Complete · Safety · 6 employees at the site · Closed Jan 5, 1995

101 East Cary St., Richmond, VA 23219 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$225$112Nov 4, 1994Final
Citation 1, item 1b
29 CFR 1926.59(e)(1)(i) · Hazard communication
Serious$0$0Nov 4, 1994Final
Citation 1, item 1c
29 CFR 1926.59(g)(8) · Hazard communication
Serious$0$0Nov 4, 1994Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$375$188Nov 4, 1994Final
Citation 1, item 3
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$375$188Nov 4, 1994Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.59 · Hazard communication

Other masonry contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.