Inspection 348061854 OPENED FEB 24, 2025Closed
801 John C Watts Drive, Nicholasville, KY 40356 · Motor Vehicle Seating and Interior Trim Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Nicholasville, Kentucky · Paint and Coating Manufacturing · NAICS 325510
OSHA has inspected Creative Liquid Coatings Inc 4 times in Kentucky since 2022.
The latest one began on Feb 24, 2025 on a referral, in Nicholasville.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $21,000 and still stand at $21,000.
Working near live electrical parts comes up most often in these citations: 2 items under 1910.333.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Creative Liquid Coatings Inc averages $21,000 (1 cited inspection).
Creative Liquid Coatings Inc also files yearly injury logs with OSHA, summarized below.
Kentucky · latest 90 days of OSHA records
184employers cited
Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kentucky
Checking a subcontractor, a client or your own company? Watch Creative Liquid Coatings Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Creative Liquid Coatings Inc at 3 sites in 3 states. Together they've had 11 inspections and $35,436 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans801 John C Watts Drive, Nicholasville, KY 40356 · Motor Vehicle Seating and Interior Trim Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 John C Watts Drive, Nicholasville, KY 40356 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 John C Watts Drive, Nicholasville, KY 40356 · Motor Vehicle Seating and Interior Trim Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $7,000 | $7,000 | Feb 1, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.333(b)(2)(iii)(a) · Working near live electrical parts |
Serious | $7,000 | $7,000 | Feb 1, 2024 | Final |
| Citation 1, item 3 29 CFR 1910.333(b)(2)(iv) · Working near live electrical parts |
Serious | $7,000 | $7,000 | Feb 1, 2024 | Final |
801 John C Watts Drive, Nicholasville, KY 40356 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Nicholasville site logged 6 recordable injuries or illnesses among about 177 workers: 3.2 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 60 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Creative Liquid Coatings, Inc. Nicholasville Nicholasville · 2025 | 177 | 6 | 2 | 3.2 | 2.7 |
| Creative Liquid Coatings, Inc Nicholasville Nicholasville · 2023 | 230 | 15 | 4 | 5.4 | 2.7 |
Included with any plan: 1 more yearly log from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
29 CFR 1910.333(b)(2)(iii)(a)
(iii) Application of locks and tags. (A) A lock and a tag shall be placed on each disconnecting means used to deenergize circuits and equipment on which work is to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section. The lock shall be attached so as to prevent persons from operating the disconnecting means unless they resort to undue force or the use of tools.
29 CFR 1910.333(b)(2)(iv)
(iv) Verification of deenergized condition. The requirements of this paragraph shall be met before any circuits or equipment can be considered and worked as deenergized.
Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.