OSHA SearchOSHA records by employer

Creative Masonry, Inc.: OSHA inspections and violations

Roanoke, Virginia · Masonry Contractors · NAICS 238140

14inspections
20citation items
$19,526current penalties
Jan 6, 2026last inspection

OSHA has inspected Creative Masonry, Inc. 14 times in Virginia since 1997.

The latest one began on Jan 6, 2026, in Blacksburg; the case is still open.

Those inspections ended with 20 citation items: 16 serious and 4 other-than-serious.

Penalties were first proposed at $24,945 and now stand at $19,526, 22% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 13 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Creative Masonry, Inc. averages $4,180 (4 cited inspections).

Creative Masonry, Inc.: OSHA citation items per year, 1997 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Creative Masonry, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348675000 OPENED JAN 6, 2026Open

Unprogrammed other · Complete · Safety · 5 employees at the site · Open

414 N Main St., Blacksburg, VA 24060 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$600$510Feb 6, 2026Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$600$510Feb 6, 2026Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$600$510Feb 6, 2026Final
Citation 1, item 4
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$600$510Feb 6, 2026Final
Citation 1, item 5a
29 CFR 1926.452(b)(2) · Rules for each type of scaffold
Serious$600$510Feb 6, 2026Final
Citation 1, item 5b
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$0$0Feb 6, 2026Final

Inspection 346554769 OPENED MAR 8, 2023Closed

Unprogrammed other · Partial · Safety · 16 employees at the site · Closed Jul 6, 2023

Bristol Elementary School 200 Spring Hill Terrace, Bristol, VA 24201 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$6,635$4,644May 25, 2023Final

Inspection 346384829 OPENED DEC 12, 2022Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 4, 2023

Russell County Courthouse [new Construction] 53 West Main Street, Lebanon, VA 24266 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$3,530$2,471Feb 14, 2023Final
Citation 2, item 1
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Feb 14, 2023Final

Inspection 343939484 OPENED APR 17, 2019Closed

Unprogrammed other · Partial · Health · 8 employees at the site · Closed Nov 6, 2019

25020 Western Loop, Abingdon, VA 24210 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,820$3,820May 8, 2019Final
Citation 1, item 2
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$3,235$3,235May 8, 2019Final

Inspection 316787290 OPENED JAN 31, 2013Closed

Planned · Partial · Safety · 1 employee at the site · Closed Mar 5, 2013

Oak Point Elementary School, Marionville, VA 23408 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313699241 OPENED JUL 28, 2009Closed

Planned · Complete · Safety · 9 employees at the site · Closed Jul 28, 2009

801 E. Main St., Salem, VA 24153 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310760285 OPENED JAN 30, 2007Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 2, 2007

1831 Deyerle Road Sw, Roanoke, VA 24018 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Other-than-serious$0$0Mar 22, 2007Closed

Inspection 307358317 OPENED JUN 8, 2004Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jun 8, 2004

210 S. College Ave., Salem, VA 24153 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

6 older inspections

Inspection 306821323 OPENED OCT 28, 2003Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 28, 2003

611 Mcdowell Ave., Roanoke, VA 24016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306302472 OPENED JUN 10, 2003Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 18, 2003

611 Mcdowell Ave., Roanoke, VA 24016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(ii) · Scaffolds, general requirements
Serious$750$450Jul 24, 2003Closed

Inspection 304537871 OPENED JUL 23, 2001Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 19, 2002

1872 Pratt Drive, Blacksburg, VA 24060 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$625$375Aug 15, 2001Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$625$375Aug 15, 2001Final
Citation 1, item 3
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$625$375Aug 15, 2001Final

Inspection 304537020 OPENED MAY 31, 2001Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 27, 2001

7223 Williamson Road, Roanoke, VA 24012 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$750$450Jul 9, 2001Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$450Jul 9, 2001Closed

Inspection 304131576 OPENED MAR 1, 2001Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 3, 2001

1872 Pratt Drive, Blacksburg, VA 24060 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$300$180Mar 27, 2001Closed

Inspection 126610732 OPENED SEP 29, 1997Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 4, 1997

Colonial Ave. Towers Mall, Roanoke, VA 24014 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$300$150Oct 10, 1997Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Virginia