OSHA SearchOSHA records by employer

Csa Home Improvement, Inc.: OSHA inspections and violations

Worcester, Massachusetts · Finish Carpentry Contractors · NAICS 238350

2inspections
12citation items
$8,000current penalties
Jan 27, 2025last inspection

OSHA has inspected Csa Home Improvement, Inc. 2 times in Massachusetts since 2024.

The latest one began on Jan 27, 2025 as a planned inspection, in Westminster.

Those inspections ended with 12 citation items: 11 serious and 1 other-than-serious.

Penalties were first proposed at $38,302 and now stand at $8,000, 79% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Csa Home Improvement, Inc. averages $4,000 (2 cited inspections).

Csa Home Improvement, Inc.: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Csa Home Improvement, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348001777 OPENED JAN 27, 2025Closed

Planned · Partial · Safety · 8 employees at the site · Closed Mar 30, 2026

150 State Rd East, Westminster, MA 01473 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$4,256$500Apr 9, 2025Final
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,837$0Apr 9, 2025Final
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,965$1,000Apr 9, 2025Final
Citation 1, item 3b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Apr 9, 2025Final
Citation 1, item 3c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,965$0Apr 9, 2025Final
Citation 1, item 5
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$2,837$500Apr 9, 2025Final

Inspection 347914657 OPENED DEC 4, 2024Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 10, 2026

63 North St., Worcester, MA 01605 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$4,965$3,000Mar 19, 2025Final
Citation 1, item 2a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$4,965$3,000Mar 19, 2025Final
Citation 1, item 2b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Mar 19, 2025Final
Citation 1, item 2c
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,965$0Mar 19, 2025Final
Citation 1, item 2d
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Mar 19, 2025Final
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$3,547$0Mar 19, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other finish carpentry contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.