Inspection 345597975 OPENED OCT 25, 2021Closed
3807 Brandon Avenue Sw Suite 245, Roanoke, VA 24018 · Lessors of Residential Buildings and Dwellings · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Serious | $600 | $420 | Nov 4, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 1, item 1c 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 1, item 1d 29 CFR 1910.215(d)(3) · Grinders and abrasive wheels |
Serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 1, item 2a 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $600 | $420 | Nov 4, 2021 | Final |
| Citation 1, item 2b 29 CFR 1910.304(g)(6)(iii) · Grounding and circuit protection |
Serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 1, item 2c 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 4, 2021 | Final |
| Citation 2, item 3 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 4, 2021 | Final |