OSHA SearchOSHA records by employer

Cubic Water, LLC: OSHA inspections and violations

El Paso, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
11citation items
$22,049current penalties
Mar 8, 2019last inspection

Since 2014, OSHA inspectors have visited Cubic Water, LLC in Texas 4 times.

The most recent inspection opened on Mar 8, 2019 on a referral, in San Elizario.

In all, OSHA issued 11 citation items: 7 serious and 4 other-than-serious.

The proposed penalties came to $43,279; today they stand at $22,049, 49% less.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cubic Water, LLC averages $2,024 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Cubic Water, LLC: OSHA citation items per year, 2014 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Cubic Water, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343837241 OPENED MAR 8, 2019Closed

Referral · Complete · Safety · 10 employees at the site · Closed Aug 30, 2019

1400 Saltillo, San Elizario, TX 79849 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 4, 2019: Employee installing pipe falls into pit and fractures skull

At 1:30 p.m. on March 4, 2019, Employee #1, employed by a water and sewer line construction company, was installing a pipe for a water/sewer treatment plant construction project. As he leaned on the door to adjust the pipe, he fell. The employee struck the bottom of the pump pit, a fall height of approximately 30 feet. Emergency services transported the employee to the hospital, where he was admitted for treatment of a fractured skull.

No citations from this inspection.

Inspection 342388394 OPENED JUN 9, 2017Closed

Referral · Partial · Safety · 4 employees at the site · Closed May 7, 2018

4100 Delta Dr., El Paso, TX 79906 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$2,390$956Oct 20, 2017Final
Citation 1, item 2a
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$3,983$1,593Oct 20, 2017Final
Citation 1, item 2b
29 CFR 1926.405(j)(3)(i) · Job-site wiring
Other-than-serious$2,390$0Oct 20, 2017Final

Inspection 341244770 OPENED FEB 11, 2016Closed

Follow-up · Partial · Health · 8 employees at the site · Closed Aug 21, 2017

4100 Delta Dr., El Paso, TX 79905 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.134(h)(3)(iii) · Respiratory protection
Other-than-serious$4,116$1,500Aug 11, 2016Final

Inspection 340030857 OPENED OCT 22, 2014Closed

Fatality or catastrophe · Complete · Health · 12 employees at the site · Closed Sep 8, 2017

10001 Soutside, El Paso, TX 79927 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Oct 22, 2014 (fatal): Two employees are killed from overexposure to hydrogen sulfi

At approximately 1:00 p.m. on October 22, 2014, Employee #1 was adjusting process piping at a waste water treatment plant that had been installed when he encountered a leak. Employee #1 exited Pump Room #2 to notify Water Utilities of the leak. Employee #1 returned to Pump Room #2 to try and close the main valve from the primary clarifier to isolate the flow from the leak. After entering Pump Room #2, Employee #1 was overcome with hydrogen sulfide and unable to exit the room. Upon hearing that Employee #1 had fallen, Employee #2 then entered the room to retrieve Employee #1. Both employees were unable to exit the room and were killed from over exposure to hydrogen sulfide. sulfide.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$7,000$4,200Apr 17, 2015Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$7,000$4,200Apr 17, 2015Final
Citation 1, item 2b
29 CFR 1910.147(f)(2)(i) · Lockout/tagout
Serious$0$0Apr 17, 2015Final
Citation 1, item 3
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$2,400$1,200Apr 17, 2015Final
Citation 1, item 4a
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$7,000$4,200Apr 17, 2015Final
Citation 1, item 4b
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$0$0Apr 17, 2015Final
Citation 1, item 5
29 CFR 1910.1000(e) · Air contaminants
Serious$7,000$4,200Apr 17, 2015Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 4, 2019, San Elizario: Hospitalization · fractures · skull

At 1:30 p.m. on March 4, 2019, an employee was installing a pipe. The employee leaned on a door to adjust the pipe and fell 30 feet to the bottom of the pump pit. The employee was hospitalized for a fractured skull.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(1)(i)

(1) General requirements. (i) The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites