OSHA SearchOSHA records by employer

Cuevas Plastering LLC: OSHA inspections and violations

Bentonville, Arkansas · Drywall and Insulation Contractors · NAICS 238310

1inspections
6citation items
$7,810current penalties
Aug 27, 2019last inspection

Cuevas Plastering LLC has one OSHA inspection on record in Arkansas.

OSHA opened it on Aug 27, 2019, in Bentonville.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $15,614 in penalties. After settlements and reviews the total is $7,810, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Cuevas Plastering LLC averages $7,810 over 1 cited inspection in that time.

Cuevas Plastering LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

14employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Cuevas Plastering LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344269980 OPENED AUG 27, 2019Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Jun 19, 2020

4318 Scissortail Dr., Bentonville, AR 72712 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,470$1,735Feb 27, 2020Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$4,048$2,025Feb 27, 2020Final
Citation 1, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,048$2,025Feb 27, 2020Final
Citation 1, item 3b
29 CFR 1926.452(m)(2) · Rules for each type of scaffold
Serious$0$0Feb 27, 2020Final
Citation 1, item 4a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,048$2,025Feb 27, 2020Final
Citation 1, item 4b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Feb 27, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

Other drywall and insulation contractors employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.