OSHA SearchOSHA records by employer

Cummer Masonry, Inc.: OSHA inspections and violations

Cedar Rapids, Iowa · Commercial and Institutional Building Construction · NAICS 236220

2inspections
4citation items
$3,023current penalties
Apr 7, 2020last inspection

Since 2009, OSHA inspectors have visited Cummer Masonry, Inc. in Iowa 2 times.

The most recent inspection opened on Apr 7, 2020, in Peosta.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $6,046; today they stand at $3,023, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cummer Masonry, Inc. averages $2,273 across 1 cited inspection.

Cummer Masonry, Inc.: OSHA citation items per year, 2009 to 2020
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

69employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Cummer Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344721741 OPENED APR 7, 2020Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Aug 5, 2020

8522 Burds Rd, Peosta, IA 52068 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,546$2,273Jul 6, 2020Final

Inspection 313700791 OPENED AUG 13, 2009Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Sep 29, 2009

1815 1st Ave Se, Cedar Rapids, IA 52402 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$1,500$750Sep 4, 2009Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 4, 2009Closed
Citation 2, item 1a
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Sep 4, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.454 · Scaffold training

Other commercial and institutional building construction employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.