OSHA SearchOSHA records by employer

Custom Building Solutions: OSHA inspections and violations

Cedar Park, Texas · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
4citation items
$3,880current penalties
Nov 28, 2018last inspection

OSHA inspectors have visited Custom Building Solutions in Texas one time.

It opened on Nov 28, 2018 as a planned inspection, in Cedar Park.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $7,760; today they stand at $3,880, 50% less.

The rule cited most here is 1910.213 (woodworking machinery), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Custom Building Solutions averages $3,880 across 1 cited inspection.

Custom Building Solutions: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Custom Building Solutions again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343626008 OPENED NOV 28, 2018Closed

Planned · Partial · Health · 9 employees at the site · Closed Oct 15, 2019

2000 Windy Terrace Bldg #8, Cedar Park, TX 78613 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$1,663$832Jan 16, 2019Final
Citation 1, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$1,663$832Jan 16, 2019Final
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,217$1,108Jan 16, 2019Final
Citation 1, item 2b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$2,217$1,108Jan 16, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

Other wood kitchen cabinet and countertop manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.