OSHA SearchOSHA records by employer

Custom Cedar Products Inc: OSHA inspections and violations

Portland, Oregon · Sawmills · NAICS 321113

3inspections
18citation items
$1,590current penalties
Nov 30, 2016last inspection

Since 1993, OSHA inspectors have visited Custom Cedar Products Inc in Oregon 3 times.

The most recent inspection opened on Nov 30, 2016 after a complaint, in Portland.

In all, OSHA issued 18 citation items: 9 serious and 9 other-than-serious.

The penalties, $1,590 in total, stand where OSHA first set them.

The rule cited most here is 1910.219 (belts, pulleys and power-transmission parts), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Custom Cedar Products Inc averages $0 across 1 cited inspection.

Custom Cedar Products Inc: OSHA citation items per year, 1993 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

388employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Custom Cedar Products Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341960771 OPENED NOV 30, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed May 24, 2017

16369 Ne Sandy Blvd, Portland, OR 97230 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-002-0022(3)(F)
Other-than-serious$0$0Dec 19, 2016Final

Inspection 124715368 OPENED NOV 16, 1995Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jun 26, 1996

16369 Ne Sandy Blvd, Portland, OR 97230 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$270$270Jan 2, 1996Closed
Citation 2, item 2 Other-than-serious$0$0Jan 2, 1996Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 2, 1996Closed

Inspection 123771602 OPENED JUL 8, 1993Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 21, 2010

16369 Ne Sandy Blvd, Portland, OR 97230 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$420$420Aug 5, 1993Closed
Citation 1, item 2
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Aug 5, 1993Closed
Citation 1, item 3
29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Aug 5, 1993Closed
Citation 1, item 4
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$120$120Aug 5, 1993Closed
Citation 1, item 5
29 CFR 1910.213(f)(1) · Woodworking machinery
Serious$120$120Aug 5, 1993Closed
Citation 1, item 6
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$120$120Aug 5, 1993Closed
Citation 1, item 7
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$180$180Aug 5, 1993Closed
Citation 1, item 8
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$120$120Aug 5, 1993Closed
Citation 2, item 9
29 CFR 1910.27(b)(1)(ii) · Fixed ladders
Other-than-serious$0$0Aug 5, 1993Closed
Citation 2, item 10
29 CFR 1910.27(c)(4) · Fixed ladders
Other-than-serious$0$0Aug 5, 1993Closed
Citation 2, item 11
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Aug 5, 1993Closed
Citation 2, item 12 Other-than-serious$0$0Aug 5, 1993Closed
Citation 2, item 13 Other-than-serious$0$0Aug 5, 1993Closed
Citation 2, item 14 Other-than-serious$0$0Aug 5, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(d)(2)(ii)

(ii) Each lavatory shall be provided with hot and cold running water, or tepid running water.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(d)(1)

(d) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7020.2230

29 CFR 7020.2420

29 CFR 7650.350