OSHA SearchOSHA records by employer

Custom Fabs, Inc.: OSHA inspections and violations

Newark, New Jersey · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
2citation items
$5,784current penalties
Oct 23, 2020last inspection

OSHA inspectors have visited Custom Fabs, Inc. in New Jersey one time.

It opened on Oct 23, 2020 after a complaint, in Newark.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $5,784 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Custom Fabs, Inc. averages $5,784 across 1 cited inspection.

Custom Fabs, Inc.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

272employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Custom Fabs, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344992706 OPENED OCT 23, 2020Closed

Complaint · Partial · Health · 5 employees at the site · Closed Jun 12, 2026

49 Rutherford St., Newark, NJ 07105 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$2,892$2,892Dec 9, 2020Final
Citation 1, item 2
29 CFR 1926.652(c)(1) · Trench protection
Serious$2,892$2,892Dec 9, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(c)(1)

(1) Option (1)—Designs using appendices A, C and D. Designs for timber shoring in trenches shall be determined in accordance with the conditions and requirements set forth in appendices A and C to this subpart. Designs for aluminum hydraulic shoring shall be in accordance with paragraph (c)(2) of this section, but if manufacturer's tabulated data cannot be utilized, designs shall be in accordance with appendix D.

Other water and sewer line and related structures construction employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.