OSHA SearchOSHA records by employer

Custom Truss LLC: OSHA inspections and violations

Delray Beach, Florida · Framing Contractors · NAICS 238130

3inspections
12citation items
$20,764current penalties
Sep 28, 2017last inspection

OSHA has inspected Custom Truss LLC 3 times in Florida since 2016.

The latest one began on Sep 28, 2017 after a complaint, in Delray Beach.

Those inspections ended with 12 citation items: 7 serious and 5 other-than-serious.

Penalties were first proposed at $39,034 and now stand at $20,764, 47% lower after settlements or reviews.

Noise comes up most often in these citations: 4 items under 1910.95.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Custom Truss LLC averages $6,921 (3 cited inspections).

Custom Truss LLC: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Custom Truss LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342668134 OPENED SEP 28, 2017Closed

Complaint · Partial · Health · 30 employees at the site · Closed Dec 22, 2017

1890 West Atlantic Avenue, Delray Beach, FL 33444 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$6,972$3,486Oct 26, 2017Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$8,365$4,182Oct 26, 2017Final
Citation 2, item 1 Other-than-serious$0$0Oct 26, 2017Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Oct 26, 2017Final

Inspection 341435535 OPENED APR 28, 2016Closed

Referral · Partial · Health · 30 employees at the site · Closed Apr 19, 2017

1890 West Atlantic Avenue, Delray Beach, FL 33444 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$6,236$4,365Aug 9, 2016Final
Citation 1, item 1b Serious$0$0Aug 9, 2016Final
Citation 1, item 1c Serious$0$0Aug 9, 2016Final

Inspection 341402170 OPENED APR 15, 2016Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jul 26, 2017

1890 West Atlantic Avenue, Delray Beach, FL 33444 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$8,730$4,365Aug 29, 2016Final
Citation 1, item 2
29 CFR 1910.213(h)(3) · Woodworking machinery
Serious$8,731$4,366Aug 29, 2016Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Aug 29, 2016Final
Citation 2, item 2
29 CFR 1910.304(b)(2) · Grounding and circuit protection
Other-than-serious$0$0Aug 29, 2016Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 29, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(c)(1)(i)

(c) Toilet facilities—(1) General. (i) Except as otherwise indicated in this paragraph (c)(1)(i), toilet facilities, in toilet rooms separate for each sex, shall be provided in all places of employment in accordance with table J-1 of this section. The number of facilities to be provided for each sex shall be based on the number of employees of that sex for whom the facilities are furnished. Where toilet rooms will be occupied by no more than one person at a time, can be locked from the inside, and contain at least one water closet, separate toilet rooms for each sex need not be provided. Where such single-occupancy rooms have more than one toilet facility, only one such facility in each toilet room shall be counted for the purpose of table J-1.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.213(h)(3)

(3) An adjustable stop shall be provided to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations.

29 CFR 1910.22 · General requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other framing contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.