OSHA SearchOSHA records by employer

D&D Amalgamated dba Diapers Unlimited: OSHA inspections and violations

Kalamazoo, Michigan · Linen Supply · NAICS 812331

1inspections
15citation items
$15,750current penalties
May 19, 2022last inspection

OSHA inspectors have visited D&D Amalgamated dba Diapers Unlimited in Michigan one time.

It opened on May 19, 2022 as a planned inspection, in Kalamazoo.

In all, OSHA issued 15 citation items: 14 serious and 1 other-than-serious.

The proposed penalties came to $31,900; today they stand at $15,750, 51% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. D&D Amalgamated dba Diapers Unlimited averages $15,750 across 1 cited inspection.

D&D Amalgamated dba Diapers Unlimited: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

617employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch D&D Amalgamated dba Diapers Unlimited and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345968960 OPENED MAY 19, 2022Closed

Planned · Complete · Safety · 28 employees at the site · Closed Feb 22, 2023

814 Nola St., Kalamazoo, MI 49007 · Linen Supply · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.10632(1)
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 1b
29 CFR 408.10645(2)
Serious$0$0Aug 3, 2022Final
Citation 1, item 2
29 CFR 408.10727(1)
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 3a
29 CFR 408.13308(1)
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 3b
29 CFR 408.13308(3)
Serious$0$0Aug 3, 2022Final
Citation 1, item 4a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 4b
29 CFR 1910.303(b)(6) · Electrical equipment, general requirements
Serious$0$0Aug 3, 2022Final
Citation 1, item 5a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 5b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Aug 3, 2022Final
Citation 1, item 6
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 7a
29 CFR 408.17111(B)
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 7b
29 CFR 408.17111(C)
Serious$0$0Aug 3, 2022Final
Citation 1, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,500$1,750Aug 3, 2022Final
Citation 1, item 9
29 CFR 325.47201(3)
Serious$3,500$1,750Aug 3, 2022Final
Citation 2, item 1
29 CFR 408.22141(2)
Other-than-serious$400$0Aug 3, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:

29 CFR 1910.305 · Electrical wiring methods

Other linen supply employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.