OSHA SearchOSHA records by employer

D&D Builders: OSHA inspections and violations

Waterford, Connecticut · Framing Contractors · NAICS 238130

3inspections
12citation items
$2,621current penalties
Jul 25, 2019last inspection

D&D Builders has 3 OSHA inspections on record in Connecticut, the first in 1987.

OSHA's last visit started on Jul 25, 2019, in Griswold.

Across those inspections OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

OSHA proposed $4,672 in penalties. After settlements and reviews the total is $2,621, down 44%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. D&D Builders averages $1,421 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

D&D Builders: OSHA citation items per year, 1987 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites D&D Builders again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344180005 OPENED JUL 25, 2019Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Nov 28, 2022

122 Pleasant View Street, Griswold, CT 06351 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,842$1,421Aug 16, 2019Final

Inspection 109851709 OPENED SEP 21, 2000Closed

Accident · Complete · Safety · 3 employees at the site · Closed Feb 2, 2001

Lot #6 Weed Road, Torrington, CT 06790 · OSHA's record · Phone and website on Google Maps

Incident on Sep 21, 2000 (fatal): Employee killed in fall from roof

Employee #1 was killed when he fell 27 ft from a roof to the ground.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,000Dec 11, 2000Closed
Citation 1, item 1b
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$0$0Dec 11, 2000Closed

Inspection 100177542 OPENED MAR 24, 1987Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 29, 1987

356 Boston Post Road, Waterford, CT 06385 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(f) · Woodworking tools
Serious$120$80May 14, 1987Closed
Citation 1, item 2a
29 CFR 1926.451(a)(10) · Scaffolds, general requirements
Serious$210$120May 14, 1987Closed
Citation 1, item 2b
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Serious$0$0May 14, 1987Closed
Citation 1, item 2c
29 CFR 1926.451(y)(4)(i) · Scaffolds, general requirements
Serious$0$0May 14, 1987Closed
Citation 1, item 2d
29 CFR 1926.451(y)(4)(iii) · Scaffolds, general requirements
Serious$0$0May 14, 1987Closed
Citation 1, item 2e
29 CFR 1926.451(y)(5) · Scaffolds, general requirements
Serious$0$0May 14, 1987Closed
Citation 1, item 2f
29 CFR 1926.451(y)(11) · Scaffolds, general requirements
Serious$0$0May 14, 1987Closed
Citation 2, item 1
29 CFR 1926.405(a)(2)(iij) · Job-site wiring
Other-than-serious$0$0May 14, 1987Closed
Citation 2, item 2
29 CFR 1926.405(a)(2)(iij) · Job-site wiring
Other-than-serious$0$0May 14, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(f)

(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iij)

(J) Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Connecticut

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.