D&D Global LLC: OSHA inspections and violations

Fort Lauderdale, Florida · Landscaping Services · NAICS 561730

1inspections
2citation items
$13,982current penalties
Feb 12, 2021last inspection

OSHA inspectors have visited D&D Global LLC in Florida one time.

It opened on Feb 12, 2021 after a fatality or catastrophe, in Fort Lauderdale and is still open.

In all, OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

The penalties, $13,982 in total, stand where OSHA first set them.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,208 penalty. D&D Global LLC averages $13,982 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

D&D Global LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch D&D Global LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345149769 OPENED FEB 12, 2021Open

Fatality or catastrophe · Complete · Safety · 3 employees at the site · Open

2523 Ne 23 Street, Fort Lauderdale, FL 33305 · Landscaping Services · OSHA's record · Phone and website on Google Maps

Incident on Feb 12, 2021 (fatal): Employee is killed after contacting overhead power line whil

At 11:30 a.m. on February 12, 2021, an employee was cutting palm fronds while standing on a 28-foot Werner aluminum extension ladder and using a 16-foot Silky aluminum pole saw. While the employee was using the pole saw the tool slipped and contacted an energized 7.62 kilovolt overhead power line located approximately 3 feet from the palm tree. The employee received an electric shock and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(c)(3)(i)(a)(1) · Working near live electrical parts
Serious$13,653$13,653Jul 16, 2021Final
Citation 2, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$329$329Sep 30, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(i)(a)(1)

(i) Unqualified persons. (A) When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances: