OSHA SearchOSHA records by employer

D C Miller Construction, LLC: OSHA inspections and violations

Peninsula, Ohio · Siding Contractors · NAICS 238170

1inspections
4citation items
$11,952current penalties
Jul 5, 2017last inspection

OSHA has inspected D C Miller Construction, LLC once in Ohio.

The inspection began on Jul 5, 2017 as a planned inspection, in Peninsula; the case is still open.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $11,952 and still stand at $11,952.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and D C Miller Construction, LLC averages $11,952 (1 cited inspection).

D C Miller Construction, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch D C Miller Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342453438 OPENED JUL 5, 2017Open

Planned · Partial · Safety · 4 employees at the site · Open

30 Salt Creek, Peninsula, OH 44264 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,630$1,630Jul 11, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,803$3,803Jul 11, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,803$3,803Jul 11, 2017Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,716$2,716Jul 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other siding contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.