Inspection 346448145 OPENED JAN 18, 2023Closed
3294 St George Road, Williston, VT 05495 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bennington, Vermont · Commercial and Institutional Building Construction · NAICS 236220
D.E.W. Construction Corp. has 12 OSHA inspections on record in Vermont, the first in 1999.
OSHA's last visit started on Jan 18, 2023 as a planned inspection, in Williston.
Across those inspections OSHA issued 6 citation items: 1 serious and 5 other-than-serious.
OSHA proposed $8,735 in penalties. After settlements and reviews the total is $5,272, down 40%.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. D.E.W. Construction Corp. averages $2,461 over 2 cited inspections in that time.
Want to know if OSHA cites D.E.W. Construction Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company3294 St George Road, Williston, VT 05495 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
115 Rockingham Street, Bellows Falls, VT 05101 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.150(a)(3) · Fire protection |
Other-than-serious | $0 | $0 | Oct 3, 2022 | Final |
| Citation 2, item 2 29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction |
Other-than-serious | $814 | $485 | Oct 3, 2022 | Final |
115 Rockingham Street, Bellows Falls, VT 05101 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(d)(16) · Fall protection systems |
Unclassified | $7,396 | $4,437 | Sep 19, 2022 | Final |
241 S. Main St., White River Junction, VT 05001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
207 Flynn Avenue, Burlington, VT 05401 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
200 Veterans Memorial Drive, Bennington, VT 05201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rt 15 West, Johnson, VT 05656 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rt 15 West, Johnson, VT 05656 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(13) · Fall protection in construction |
Other-than-serious | $525 | $350 | Mar 27, 2002 | Closed |
| Citation 1, item 1b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Other-than-serious | $0 | $0 | Mar 27, 2002 | Closed |
82 South Winooski Avenue, Burlington, VT 05401 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Gage St, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
207 Stratton Road, Rutland, VT 05701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1926.405(a)(2)(iic) · Job-site wiring |
Serious | $0 | $0 | Jun 2, 1999 | Closed |
Gage St, Bennington, VT 05201 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(a)(3)
(3) All firefighting equipment, provided by the employer, shall be conspicuously located.
29 CFR 1926.405(a)(2)(iic)
(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.
29 CFR 1926.501(b)(13)
(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.