OSHA SearchOSHA records by employer

D-Stucco LLC: OSHA inspections and violations

Laramie, Wyoming · Siding Contractors · NAICS 238170

1inspections
3citation items
$6,000current penalties
Aug 4, 2016last inspection

D-Stucco LLC has one OSHA inspection on record in Wyoming.

OSHA opened it on Aug 4, 2016 as a planned inspection, in Laramie.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $6,000 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. D-Stucco LLC averages $6,000 over 1 cited inspection in that time.

D-Stucco LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch D-Stucco LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341697886 OPENED AUG 4, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 2, 2023

1810 Pinnacle, Laramie, WY 82070 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$2,000$2,000Dec 2, 2016Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,000$2,000Dec 2, 2016Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000Dec 2, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.95 · Criteria for personal protective equipment

29 CFR 1926.95(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

Other siding contractors employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.