Daf Framing, Inc.: OSHA inspections and violations

Mansfield, Texas · Framing Contractors · NAICS 238130

2inspections
3citation items
$3,579current penalties
Jan 24, 2017last inspection

OSHA has inspected Daf Framing, Inc. 2 times in Texas since 2011.

The latest one began on Jan 24, 2017 as a planned inspection, in Arlington.

Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $6,970 and now stand at $3,579, 49% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Daf Framing, Inc. averages $2,535 (1 cited inspection).

Daf Framing, Inc.: OSHA citation items per year, 2011 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Daf Framing, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342055837 OPENED JAN 24, 2017Closed

Planned · Partial · Safety · 14 employees at the site · Closed Aug 29, 2017

425 E. Lamar, Arlington, TX 76011 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,070$2,535May 10, 2017Final

Inspection 316043827 OPENED NOV 9, 2011Closed

Planned · Partial · Safety · 12 employees at the site · Closed Jan 11, 2012

870 N. Sh 360, Mansfield, TX 76063 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$1,800$990Nov 25, 2011Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$100$54Nov 25, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.