OSHA SearchOSHA records by employer

Dagoberto Torres: OSHA inspections and violations

Cary, North Carolina · Residential Remodelers · NAICS 236118

1inspections
3citation items
$8,400current penalties
May 30, 2017last inspection

OSHA has inspected Dagoberto Torres once in North Carolina.

The inspection began on May 30, 2017 as a planned inspection, in Cary.

That inspection ended with 3 citation items: 1 serious, 1 repeat and 1 other-than-serious.

Penalties were first proposed at $8,400 and still stand at $8,400.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dagoberto Torres averages $8,400 (1 cited inspection).

Dagoberto Torres: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Dagoberto Torres and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342366168 OPENED MAY 30, 2017Closed

Planned · Complete · Safety · 6 employees at the site · Closed Feb 3, 2022

2400 Brook Arbor Dr., Cary, NC 27513 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$5,600$5,600Jul 18, 2017Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,800$2,800Jul 18, 2017Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jul 18, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(11)

(11) Steep roofs. Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(b)(1)

(b) Certification of training. (1) The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.