OSHA SearchOSHA records by employer

Dale Cox Contracting: OSHA inspections and violations

Ephraim, Utah · Poured Concrete Foundation and Structure Contractors · NAICS 238110

8inspections
18citation items
$13,370current penalties
Jun 4, 2019last inspection

Since 1987, OSHA inspectors have visited Dale Cox Contracting in Utah 8 times.

The most recent inspection opened on Jun 4, 2019 as a planned inspection, in Layton.

In all, OSHA issued 18 citation items: 13 serious and 5 other-than-serious.

The proposed penalties came to $33,620; today they stand at $13,370, 60% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Dale Cox Contracting averages $1,500 across 1 cited inspection.

Dale Cox Contracting: OSHA citation items per year, 1987 to 2019
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Dale Cox Contracting and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344056189 OPENED JUN 4, 2019Closed

Planned · Partial · Safety · 15 employees at the site · Closed Sep 20, 2019

Valley View Water Tank Valley View Drive, Layton, UT 84040 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$21,000$1,500Jul 10, 2019Final

Inspection 340475490 OPENED MAR 17, 2015Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jun 19, 2015

700 N Main, Ephraim, UT 84627 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314195298 OPENED JUN 8, 2011Closed

Referral · Partial · Safety · 13 employees at the site · Closed Nov 1, 2011

4 Mile Mark, Ephraim Canyon Rd, Ephraim, UT 84627 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Sep 26, 2011Closed

Inspection 310454541 OPENED FEB 15, 2007Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jun 5, 2007

Santa Clara Dr., Santa Clara, UT 84765 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,000$2,000Apr 16, 2007Closed
Citation 1, item 2
29 CFR 1926.602(a)(1) · Earthmovers and forklifts in construction
Serious$2,000$2,000Apr 16, 2007Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Apr 16, 2007Closed

Inspection 310453873 OPENED JAN 16, 2007Closed

Accident · Complete · Safety · 15 employees at the site · Closed Oct 16, 2007

Zone 3 Culunary Water Tank, Fox Hollow Dev., Saratoga Springs, UT 84043 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$2,000$2,000Mar 27, 2007Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Mar 27, 2007Closed
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Mar 27, 2007Closed
Citation 1, item 1d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 27, 2007Closed
Citation 1, item 2
29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete
Serious$2,000$2,000Mar 27, 2007Closed

Inspection 309169860 OPENED JUN 14, 2006Closed

Accident · Partial · Safety · 12 employees at the site · Closed Jan 5, 2007

15090 S. Deer Ridge Rd., Draper, UT 84020 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$1,500Dec 5, 2006Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Dec 5, 2006Closed
Citation 2, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Dec 5, 2006Closed

Inspection 102095999 OPENED JUN 22, 1987Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 22, 1987

800 East 300 South, North Salt Lake City, UT 84054 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR CON05000402
Other-than-serious$0$0Jun 29, 1987Closed
Citation 1, item 2
29 CFR CON05500106
Other-than-serious$0$0Jun 29, 1987Closed
Citation 1, item 3
29 CFR CON05500119
Other-than-serious$0$0Jun 29, 1987Closed

Inspection 105640395 OPENED APR 2, 1987Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 25, 1987

1900 West 1600 South, Ogden, UT 84404 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR CON065103
Serious$120$120Apr 13, 1987Closed
Citation 1, item 1b
29 CFR CON065213
Serious$0$0Apr 13, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.703 · Requirements for cast-in-place concrete

Other poured concrete foundation and structure contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.