Dalo Construction Inc.: OSHA inspections and violations

Suffolk, Virginia · Commercial and Institutional Building Construction · NAICS 236220

2inspections
3citation items
$441current penalties
Jul 31, 2015last inspection

OSHA has inspected Dalo Construction Inc. 2 times in Virginia since 2010.

The latest one began on Jul 31, 2015 as a planned inspection, in Purcellville.

Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $735 and now stand at $441, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dalo Construction Inc. averages $0 (1 cited inspection).

Dalo Construction Inc.: OSHA citation items per year, 2010 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Dalo Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340817428 OPENED JUL 31, 2015Closed

Planned · Partial · Safety · 1 employee at the site · Closed Sep 28, 2015

165 Purcellville Gateway Drive, Purcellville, VA 20132 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Sep 14, 2015Final

Inspection 314909698 OPENED SEP 2, 2010Closed

Planned · Partial · Safety · 1 employee at the site · Closed Apr 19, 2011

6212 College Dr., Suffolk, VA 23435 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$420$252Oct 5, 2010Closed
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$315$189Oct 5, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(ii)

(ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.

Other commercial and institutional building construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.