OSHA SearchOSHA records by employer

Dan-Loc Group, LLC.: OSHA inspections and violations

Piqua, Ohio · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

1inspections
3citation items
$6,630current penalties
Aug 28, 2019last inspection

OSHA has inspected Dan-Loc Group, LLC. once in Ohio.

The inspection began on Aug 28, 2019 after a complaint, in Piqua.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $26,520 and now stand at $6,630, 75% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 3 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dan-Loc Group, LLC. averages $6,630 (1 cited inspection).

Dan-Loc Group, LLC.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Dan-Loc Group, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344266366 OPENED AUG 28, 2019Closed

Complaint · Partial · Safety · 8 employees at the site · Closed May 18, 2020

294 Fox Dr., Piqua, OH 45356 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$13,260$6,630Oct 30, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Oct 30, 2019Final
Citation 1, item 1c
29 CFR 1910.147(d) · Lockout/tagout
Serious$13,260$0Oct 30, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:

Other fabricated pipe and pipe fitting manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.