OSHA SearchOSHA records by employer

Daniel Portilla dba Daniel Portilla: OSHA inspections and violations

Pfafftown, North Carolina · Framing Contractors · NAICS 238130

1inspections
3citation items
$1,000current penalties
Jan 28, 2015last inspection

OSHA has inspected Daniel Portilla dba Daniel Portilla once in North Carolina.

The inspection began on Jan 28, 2015 as a planned inspection, in Pfafftown; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $1,500 and now stand at $1,000, 33% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Daniel Portilla dba Daniel Portilla averages $1,000 (1 cited inspection).

Daniel Portilla dba Daniel Portilla: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

51 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Daniel Portilla dba Daniel Portilla and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317945111 OPENED JAN 28, 2015Open

Planned · Complete · Safety · 4 employees at the site · Open

4368 Wedge Drive, Pfafftown, NC 27040 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.306(b)(3)(i) · Air receivers
Serious$300$250Feb 20, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$400Feb 20, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$600$350Feb 20, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.306 · Air receivers

29 CFR 1926.306(b)(3)(i)

(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other framing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.