OSHA SearchOSHA records by employer

Daniel Vazquez Amigo Roofing and Contracting, LLC: OSHA inspections and violations

Holly Hill, Florida · Roofing Contractors · NAICS 238160

1inspections
3citation items
$28,200current penalties
Nov 1, 2023last inspection

Daniel Vazquez Amigo Roofing and Contracting, LLC has one OSHA inspection on record in Florida.

OSHA opened it on Nov 1, 2023 after a fatality or catastrophe, in Holly Hill, and the case has not closed yet.

From that inspection OSHA issued 3 citation items: 1 serious, 1 repeat and 1 other-than-serious.

OSHA proposed $28,200 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Daniel Vazquez Amigo Roofing and Contracting, LLC averages $28,200 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Daniel Vazquez Amigo Roofing and Contracting, LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Daniel Vazquez Amigo Roofing and Contracting, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347075913 OPENED NOV 1, 2023Open

Fatality or catastrophe · Partial · Safety · 1 employee at the site · Open

1530 State Avenue, Holly Hill, FL 32117 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 31, 2023 (fatal): Employee is killed in fall through skylight to concrete floo

At 4:57 p.m. on October 31, 2023, an employee working as a roofer for a roofing contractor had traveled up a low slope roof that had 8-flush mounted skylights. The employee was not using a personal fall protection system and the skylights were not protected with either guardrails or covers. The employee was tasked with identifying leaking areas for resealing. The employee had taken a video and texted it to the property owner with his observations on the roof. There were no witnesses or video footage as to what the employee was actually doing at the time. The employee fell through the northeast skylight and was found on the concrete floor of the warehouse. The employee had died from blunt force trauma to the head.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$16,131$16,131Apr 26, 2024Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$10,646$10,646Apr 26, 2024Final
Citation 3, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$1,423$1,423Sep 16, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(4)(i)

(4) Holes. (i) Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.